Connect Profinet IO to BACnet/IP Client

Connects a PROFINET IO Controller with a BACnet/IP Client

460PSBS

$896.72$1,251.75

SKU: 460PSBS

INCLUDES
PRODUCT FEATURES
DATASHEETS & USERGUIDES

Get Your Profinet IO Controller Connected to a BACnet/IP Client
The 460PSBS moves data between a Profinet IO Controller and a BACnet/IP Client. With the 460PSBS you are making a direct connection between Profinet IO data and your BACnet/IP Building Automation System.

How Do I Use the 460PSBS in My Application?
BACnet/IP Client data will be mapped into 10 Profinet IO slots. Each slot will be assigned a type of Int8, int16, int32, int64, Uint8, Uint16, Uint32, Uint64, float, double, binary8, binary16, binary32, or Short String. The slot can consist of up to 128 bytes of data from your BACnet/IP device that your Profinet IO Controller will view as Profinet data. When writing from your Profinet IO Controller, Profinet IO data will be presented to your BACnet/IP Client as BACnet/IP data.

It’s really that simple. Need to modify your data as it passes from one protocol to the other? No problem. Each data mapping you apply can be modified with up to 3 mathematic functions. Add 4 to a value, multiply by 4 and divide by 10 with ease.

Why Use Real Time Automation as a Gateway Supplier?
The 460PSBMS provides an option to access Profinet IO data on your BACnet/IP Building Automation System. While there are certainly a number of other companies offering stand alone gateways, there is no one who provides the level of support and service that you receive from RTA.

When you call a live person answers the phone. When you talk with sales you will get honest answers and recommendations, even if that means recommending someone else’s solution. When you get support it is from an engineer who had a hand in the product’s development and support doesn’t require a ticket or 24 hour wait. We are unashamed of the fact that we are a smaller company because that means you mean a lot more to us. Try the RTA difference today!

Profinet IO Server Features

Maximum Number of Slots: 10 Slots in, 10 Slots out
Slot Size: 8, 16, 32, 64 or 128 Bytes
Each Slot Can be Defined for a Single Data Type of: Int8, int16, int32, int64, UInt8, Uint16, Uint32, Uint64, float, double, binary8, binary16 or binary32
Total Data Supported: 1280 Bytes
Maximum Profinet IO Controller Connections: 1

BACnet/IP Server Features

BACnet/IP Operation Modes: BACnet/IP Server
Supported Object Types: Device, Binary I/O, Analog I/O, Character String Value
Supported Service Codes: Read & Read Multiple-B, Write & Write Multiple-B, COV & COV unsolicited-B, Device Dynamic Binding, Dynamic Object Binding-B, Device Communication Control-B
Maximum Connections: 1
Analog Objects Supported: 1200 Input and 1200 Output
Binary Objects Supported: 1600 Input and 1600 Output