The Easiest Way to Integrate ASCII Data into a Siemens S7 PLC
The 460ASC moves data between a serial ASCII device and up to 5 Siemens S7 PLCs.
With the 460ASC you now have a solution to get ASCII weather stations, UPS systems, and any other ASCII devices that output a compound ASCII string connected to your Siemens S7 PLC.
How do I use 460ASC in my application?
Incoming and outgoing ASCII data are mapped to and from memory table addresses in your Siemens S7 PLC. One area is Output only locations sending data to the ASCII device. The other is Input blocks to receiving data from your ASCII device.
If your device uses delimiters the 460ASC can be configured to automatically remove them. If you need to parse your data, the 460ASC can parse a string of ASCII data in up to 50 segments by delimiter or offset.
Why Use Real Time Automation as a Gateway Supplier?
While there are certainly other companies offering protocol gateways, there is no one who provides the level of support and service that you receive from RTA.
When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24-hour wait.
ASCII Device Features
Operation Modes: Bidirectional ASCII Transmit and ReceiveMaximum Number of Devices Supported: 2
Maximum Number of ASCII Characters Transferred: 1024 in each direction
Delimiter Processing: Incoming delimiters automatically removed; Outgoing delimiters automatically added
Parsing: Parse string of ASCII data in up to 50 segments by delimiter or offset
Concatenation: Concatenate up to 50 segments/strings of ASCII data with optional delimiter
S7 Client Features
PLC Support: S7 300/400/1200/1500Maximum Number of PLCs Supported: 5
Maximum Number of Inputs per PLC: 150
Maximum Number of Outputs per PLC: 150
Array Support: Yes, for all data types
Supported Data Types: 8Bit Int, 16Bit Int, 32Bit Int, 32Bit Float, Bool and String
What our Customers are Saying
“I challenged a customer to get it working by the time I got back from his break room with a Coke and he indeed had it working when I got back. He then said, "It’s worth twice the price!"”
Eric P. / Kendall Electric
“Everything seems to be working as we imagined. Thanks for the great response time. I did not see any way to save the configuration other than screen shots, but the configuration did not get lost in the update. Thanks again, and you were a pleasure to work with.”
Kevin L. / Extol, Inc.