Connect EtherNet/IP to Profibus

Connects an EtherNet/IP Scanner with a Profibus DP Controller

460ESPBS

$941.28$957.03

SKU: 460ESPBS

INCLUDES
PRODUCT FEATURES
DATASHEETS & USERGUIDES

Connect an EtherNet/IP Scanner Device to a Profibus Controller
The 460ESPBS moves data between an EtherNet/IP Scanner and a Profibus DP Controller. It’s the perfect tool to tie all the EtherNet/IP devices in your automation system to Profibus. Best of all the product is Made in the USA, is always in stock and comes with 5 year warranty.

How Do I Use the 460ESPBS-NNPB in My Application?
You can map up to 244 bytes of data in both direction between the two controllers. EtherNet/IP IO data is mapped to and from Profibus slots. It’s really that simple. Need to modify your data as it passes from one protocol to the other? No problem. Each data mapping you apply can be modified with up to 3 mathematic functions. Add 4 to a value, multiply by 4 and divide by 10 with ease.

Why Use Real Time Automation as a Gateway Supplier?
While there are certainly other companies offering protocol gateways, there is no one who provides the level of support and service that you receive from RTA.

When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24-hour wait.

Try the RTA difference today.

Ethernet/IP Adapter Features

Operation Modes: EtherNet/IP Adapter
Message Support: Implicit, Explicit UCMM
Data Types: BIT8,16 & 32; INT8, 16, 32 & 64; UINT8,16, 32 & 64; Float & Double
Maximum EtherNet/IP Scanner Devices: Up to 10 can listen, only one can write I/O
Max Data Per Adapter Connection: Up to 480 bytes in each direction

Profibus Slave Features

Object Model: 10 Slots in each direction
Slot Size: 2, 4, 8, 16, 24, 32 Bytes
Data Representation: int8, int16, int32, int64, uint8, uint16, uint32, uint64, Float, Double, binary8, binary 16, binary 32, Short String
Total Data Supported: 244 Bytes in each direction
Maximum Profibus DP Connections: 1