Allen-Bradley PLC to OPC UA

Allen-Bradley PLC to OPC UA

460ETCUS

$896.72$1,251.75

SKU: 460ETCUS

INCLUDES
PRODUCT FEATURES
DATASHEETS & USERGUIDES

Access Allen-Bradley PLCs via OPC UA

The 460ETCUS moves data between Allen-Bradley PLCs and up to three OPC UA clients.

Best of all, the product is made in the USA, is always in stock, and comes with 5-year warranty.

How do I use 460ETCUS in my application?

You define and inbound and outbound blocks of tags in the data table of your PLC. Tag or Register data from the Allen-Bradley PLC is mapped to OPC nodes. The data moves bidirectionally.

It’s really that simple to convert data to the information systems you need to monitor your application.

Why Use Real Time Automation as a Gateway Supplier?

While there are certainly other companies offering protocol gateways, there is no one who provides the level of support and service that you receive from RTA.

When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24-hour wait.

Ethernet/IP Tag Client Features

PLC Support: ControlLogix, CompactLogix, MicroLogix, SLC’s, PLC5E’s, NetENI
Maximum Number of PLCs Supported: 1
Messaging Support: User Selectable Connected or Unconnected Messaging
Message Transfer Modes: Direct Tag Transfer or EtherNet/IP Adapter Communications
EtherNet/IP Adapter Support: Input Assembly: 100 - 416 bytes, Output Assembly: 112 - 416 bytes
Maximum EtherNet/IP Adapter Assembly Size: 416 data bytes
IP Addressing: Dynamic (DHCP) or Static

OPC UA Server Features

Operation Mode: opc.tcp/binary with no Security
Simultaneous Connections Supported: 3
Max Number of Input Nodes per Node Type: 200
Max Number of Output Nodes per Node Type: 200
Array Support: Boolean, Integer, Unsigned Int and Float
Profiles Supported: UA 1.03 Micro Embedded Server and Data Access