Connect Modbus TCP/IP to BACnet MS/TP

Connects up to 32 Modbus TCP Servers with as many as 32 BACnet MS/TP Subordinates

460MCBM

$896.72$1,251.75

SKU: 460MCBM

INCLUDES
PRODUCT FEATURES
DATASHEETS & USERGUIDES

Connect Modbus TCP/IP Servers to BACnet MS/TP Devices
The 460MCBM moves data between a network of up to 32 Modbus TCP/IP Servers and up to 32 BACnet MS/TP devices. It’s a perfect tool to move data between your Modbus power meters, boilers, chillers or other Server devices and your BACnet MS/TP devices.

How Do I Use the 460MCBM-N34 in My Application?
For most applications the mapping is very straight forward. Modbus Register data is mapped to BACnet Analog objects and Modbus Coil data is mapped to Binary objects on BACnet. The only additional piece required for BACnet is adding meta data which is nothing more than an ASCII description of each object. No other deep understanding of either protocol is required to configure the gateway.

It really is that simple.

Why Use Real Time Automation as a Gateway Supplier?
While there are certainly other companies offering protocol gateways, there is no one who provides the level of support and service that you receive from RTA.

When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24-hour wait.

Coming soon on our new dual Ethernet hardware, click for more information!

Modbus TCP/IP Server Features

Modbus Operation Modes: Modbus TCP/IP Server
Function Codes Supported: 1, 2, 3, 4, 5, 6, 7, 15 & 16
Swapping: Byte and Word Swapping
Maximum Modbus TCP/IP Client Connections: 10
Contiguous Data Areas: 200 Total - 100 reads & 100 writes
Data Area Limits: 500 Contiguous Coils or 500 Contiguous Registers

BACnet MS/TP Slave Features

BACnet/ MS/TP Operation Modes: BACnet MS/TP Master Responder
Supported Object Types: Device, Binary I/O, Analog I/O, Character String Value
Supported Service Codes: Read & Read Multiple-B, Write & Write Multiple-B, COV & COV unsolicited-B, Device Dynamic Binding, Dynamic Object Binding-B, Device Communication Control-B
Maximum Connections: 1
Analog Objects: Supported 1200 Input and 1200 Output
Binary Objects: Supported 1600 Input and 1600 Output

What our Customers are Saying

“I challenged a customer to get it working by the time I got back from his break room with a Coke and he indeed had it working when I got back. He then said, "It’s worth twice the price!"”

Eric P. / Kendall Electric

“Everything seems to be working as we imagined. Thanks for the great response time. I did not see any way to save the configuration other than screen shots, but the configuration did not get lost in the update. Thanks again, and you were a pleasure to work with.”

Kevin L. / Extol, Inc.