Modbus RTU Servers to BACnet/IP

Connects up to 32 Modbus RTU Servers with as many as 32 BACnet /IP Servers

460MMBC

$896.72$1,251.75

SKU: 460MMBC

INCLUDES
PRODUCT FEATURES
DATASHEETS & USERGUIDES

Connect Modbus RTU Slaves to BACnet/IP Server Devices
The 460MMBM moves data between a network of up to 32 Modbus RTU Servers and up to 32 BACnet/IP devices.

With the 460MMBM, you’re mapping Modbus coil and register data directly to BACnet/IP as binary and analog values.

How do I Use 460MMBC in My Application?
Modbus register data is mapped to BACnet analog objects and Modbus coil data is mapped to binary objects. The only additional piece required for BACnet is adding meta data which is nothing more than an ASCII description of each object.

It really is that simple.

Why Use Real Time Automation as a Gateway Supplier?
While there are certainly other companies offering protocol gateways, there is no one who provides the level of support and service that you receive from RTA. When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24-hour wait.

Try the RTA difference today.

Modbus RTU Master Features

Modbus Operation Modes: Modbus RTU Master
Function Codes Supported: 1, 2, 3, 4, 5, 6, 15 & 16
Swapping: Byte and Word Swapping
Maximum Modbus RTU Slave Devices: 32
Number Read/Write Scan Lines per RTU Slave Device: 200 Total - 100 reads & 100 writes
Scan Line Support: Up to 125 Registers or 512 Coils

BACnet/IP Client Features

BACnet/IP Operation Modes: BACnet/IP Client
Supported Object Types: Device, BI/BO/BV, AI/AO/AV, MI/MO/MV, Character String Value
Supported Service Codes: Read Property-A, Read Property Multiple-A, Write Property-A, Write Property Multiple-A, Device Dynamic Binding-A
Maximum Connections: 32
Number Read/Write Scan Lines per Device: 200 Total - 100 reads and 100 writes
Scan Line Support: Up to 128 Objects