Connect Ethernet TCP/IP Devices to your Profinet IO Controller

Easily Connect up to 10 Ethernet TCP/IP Devices to a Profinet IO Controller

460PSTCP

$896.72$1,251.75

SKU: 460PSTCP

INCLUDES
PRODUCT FEATURES
DATASHEETS & USERGUIDES

Get Your Ethernet TCP/IP Devices Connected Directly to the Data Table of your PLC over Profinet IO
The 460PSTCP moves data between up to 10 Ethernet TCP/IP devices and a Profinet IO Controller.

With the 460PSTCP you now have a tool to help you map Profinet IO Controller data into an Ethernet TCP/IP application. You can also capture Ethernet TCP/IP data and write them to your Profinet IO Controller.

How Does the Data Move In and Out of the Profinet IO Controller?
Incoming Ethernet TCP/IP data is mapped to a series of ten 128-byte input slots on the Profinet IO network. Outgoing Ethernet TCP/IP data is mapped from a series of ten 128-byte output slots on the Profinet IO network. Up to 1024 characters can be transferred in both directions through the gateway.

It’s really that simple. Need to modify your data as it passes from one protocol to the other? No problem. Each data mapping you apply can be modified with up to 3 mathematic functions. Add 4 to a value, multiply by 4 and divide by 10 with ease.

Why Use Real Time Automation as a Gateway Supplier?
The 460PSTCP provides an option to access Ethernet TCP/IP devices easily with your Profinet controller. While there are certainly a number of other companies offering stand alone gateways, there is no one who provides the level of support and service that you receive from RTA.

When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations, even if that means recommending someone else’s solution. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24 hour wait. We are unashamed of the fact that we are a smaller company because that means you mean a lot more to us.

Try the RTA difference today!

Ethernet TCP/IP Device Features

Operation Modes: Client or Server
Maximum Number of Devices Supported: 10
Maximum Number of Characters Transferred: 1024
Delimiter Processing: Incoming Delimiters automatically removed; Outgoing Delimiters automatically added
Parsing: Parse String of ASCII Data in up to 50 Segments by Delimiter or Offset
Concatenation: Concatenate up to 50 segments/strings of ASCII data with optional delimiter

Profinet IO Server Features

Maximum Number of Slots: 10 Slots in, 10 Slots out
Slot Size: 8, 16, 32, 64 or 128 Bytes
Each Slot Can be Defined for a Single Data Type of: Int8, int16, int32, int64, UInt8, Uint16, Uint32, Uint64, float, double, binary8, binary16 or binary32
Total Data Supported: 1280 Bytes
Maximum Profinet IO Controller Connections: 1