Connect DH+ Devices to a PROFINET IO Gateway Controller

Connect your PROFINET IO controller with as many as 32 DH+ devices. Provide seamless communication between your DH+ devices and PROFINET protocols.

460PSDHM

$1,495.00$1,510.75

SKU: 460PSDHM

INCLUDES
PRODUCT FEATURES
DATASHEETS & USERGUIDES

Make Your Serial PLC5 or SLC 5/04 PLCs a PROFINET Device

Your legacy Allen-Bradley serial PLC can now be a PROFINET IO device on a PROFINET network. Link your DH+ Device to a PROFINET IO Gateway Controller. Keep all those old legacy PLCs from the scrap pile and extend their useful life for years to come.

How Do I Use the 460PSDHM-D2E in My Application?

For most applications, the PROFINET IO Controller Gateway mapping is very straightforward. PROFINET cyclic input and output buffers are mapped to files in the PLCs data tables. You can provide seamless communication between DH+ devices and PROFINET IO communication protocols. No message instructions and no ladder needs to be altered in the DH+ PLCs.

What Is PROFINET IO and What It Can Do for You?

Discover whether a PROFINET IO Gateway Controller aligns with your specific needs. Check out our PROFINET IO tech page — PROFINET IO, a high-level network for industrial automation applications, utilizes standard Ethernet technologies. It structures the task of exchanging data, alarms, and diagnostics with programmable controllers and other automation controllers using traditional Ethernet hardware and software.

Why Use Real Time Automation as a Gateway Supplier?

While there are certainly other companies offering protocol gateways, there is no one who provides the level of support and service that you receive from Real Time Automation. When you call us, a live person answers the phone. If you talk with our sales team, you will get honest answers and recommendations. And rest assured, all the support you get is from an engineer who had a hand in the product’s development, and support doesn’t need a ticket or 24-hour wait. We get back to you as soon as possible. It’s an RTA promise.

DH+ Features

Operation Mode: DH+ Master
PLCs Supported: 5/04, PLC5
Maximum Devices Supported: 32
Scan Lines: 100 input / 100 output
Supported Data Types: 100 Integers or 100 Binaries, or 50 floats, 82 character string per Scan line

Profinet IO Server Features

Maximum Number of Slots: 10 Slots in, 10 Slots out
Slot Size: 8, 16, 32, 64 or 128 Bytes
Each Slot Can be Defined for a Single Data Type of: Int8, int16, int32, int64, UInt8, Uint16, Uint32, Uint64, float, double, binary8, binary16 or binary32
Total Data Supported: 1280 Bytes
Maximum Profinet IO Controller Connections: 1