An overview of

AS-Interface

An I/O Solution Protocol

AS-Interface Continues to Stay in Demand

Replacing simple sensors and actuators with AS-Interface sensors and actuators is a hot trend in automation today, and for good reason. AS-Interface, already a worldwide de facto standard for simple I/O networking has the potential to cost effectively replace the rats nest of wires that permeates most industrial sites and is tremendously appealing across many industries.

Of the available low-level sensor/actuator replacement networks, AS-Interface offers the highest performance at the least cost. Due to its roots as a Siemens network, AS-Interface already enjoys the enthusiastic support of the industrial automation community in Europe. Now many automation vendors in the US are becoming attracted to its high speed, power on bus, simplicity of operation and insulation displacement wiring system.

With control engineers increasingly more comfortable with a stratified networking system, AS-Interface is the perfect solution for the lowest level in the network architecture, those simple, low-level sensors and actuators that consume the majority of installation, startup and ongoing troubleshooting expenses. Quite frankly, with the growth of AS-Interface networking, for many automation vendors it is now a mistake to not support AS-Interface.

What Is AS-Interface and Why Do I Need It in My Product?

AS-Interface is an intelligent cabling system designed to replace the discrete wires that link a programmable controller with sensors and actuators. AS-Interface provides a single cable system that is fast, easy-to-wire and easy-to-operate. Built for the simplest types of devices, AS-Interface is a master/slave system where a single AS-Interface master can exchange I/O data with up to 62 AS-Interface slave devices. Each slave can transfer up to four inputs and four outputs on a bus cycle.

AS-Interface is a standard hardware and software bus system that brings the reality of truly open systems to the lowest level of the automation business. Your customers are not just asking for connectivity at all levels of the control system, they absolutely expect and require it. Over 11,000,000 AS-Interface devices are now deployed worldwide. If you aren’t already in this game, your competitors may already be a step ahead of you.

What Is Causing This Enthusiasm for AS-Interface?

The first attraction to AS-Interface is its low cost. Cost savings are typically 15% to 40% of other bus systems using traditional cabling methods. Plus, the ongoing additional benefits of a bus system ensure enhanced operation and improved maintenance which reduce life cycle costs while improving product quality because of better performance and less downtime.

Second, the sheer blazing speed of AS-Interface attracts a lot of attention. Connected slaves are polled in turn by the AS-Interface master. A V1 network (31 devices) provides a maximum response time of 5mS per I/O point. In practice, most systems have fewer than 31 devices and the cycle times can be significantly shorter. The newer, extended AS-Interface bus with 62 devices provides a maximum response time of 10msec per I/O point, still much faster than the data acquisition and logic scans of most programmable controller systems.

Thirdly, AS-Interface is inherently deterministic and repeatable. Transmissions between the master and slave are predefined and cyclic. The time to set an output is calculable with great accuracy.

And there are other attractions to AS-Interface including a simplicity not found in any other industrial network: device power right on the network cable and no need for master or slave programming. There are no system parameters to set and devices are configured simply by identifying their device ID to the AS-Interface master.

AS-Interface is a very important technology, not only because it addresses the lowest level of a control system architecture, but also because it is backed by Siemens, the worldwide leader in industrial control. This gives it an automatic advantage in the marketplace. AS-Interface will be successful for many of the same reasons that systems like DeviceNet have been successful: strong momentum and the backing of a vendor with a huge installed base.

Like what you’re reading?

Subscribe to our Automation Education email series to learn the ins and outs of the top industrial protocols in a byte-size weekly format!

Does AS-Interface Complete with Interbus, PROFIBUS and DeviceNet?

AS-Interface can’t be compared to the Sensor bus networks DeviceNet, PROFIBUS, and Interbus. All these bus systems are more costly, support more generic communications, provide advanced diagnostic functionality and are highly configurable. These systems support very sophisticated, intelligent devices with tremendous data capabilities. Devices like drive systems, HMIs, barcode readers and the like couldn’t find a home on AS-Interface.

Maximum Number of Nodes

31 in traditional systems, 62 in V2.1

Number of I/O Points

248 I/O points (4In, 4Out per node) in V1.0, 434 (8In, 3Out per node) in V2.1

Maximum Cable Length

100m without repeaters, 300m with repeaters

Power

24VDC

Medium

Unshielded 2 wire cable for both power and data

Wiring Technology

Insulation displacement for speed and ease of installation.

Topology

Tree-structure

Typical Data Rate

All 31 nodes can be interrogated in 5msec. 10 msec for 62 node systems.

Error Detection

The AS-Interface master automatically detects invalid slave transmissions and schedules repeats

Configuration

Slaves are automatically configured with a slave address by the master or a programming tool. Masters can interrogate the network to identify connected slaves or receive an external list of slave addresses.

Addressing

Each slave gets a specific address set by the AS-Interface master or programming tool

Master-Slave Operation

A master polls each slave sequentially and awaits a response.

Hot Swap of Slave Devices

Supported

Multiple Master Operation

Not supported

Troubleshooting

AS-Interface masters automatically monitor system voltage levels and slave operation and report this data to the controller.

PLC Programming

No special knowledge of AS-Interface bus or device structure is required to program a PLC to use AS-Interface bus data. AS-Interface data is simply remote IO data to the PLC.

Discrete Device Support

Supported

Analog Device Support

Limited support in V1 and V2.1 using multiple bus cycles (12-bit analog across five bus cycles)

 

 

How to Implement AS-Interface Quickly & Effectively

Once you’ve made a decision to add AS-Interface connectivity you have a number of ways to proceed. The choices vary in time-to-market, supportability, resource requirements and price.

  1. Use an Off-the-Shelf Serial Gateway

    An off-the-shelf serial gateway is the least economical approach with the fastest time-to-market. To implement a serial gateway your product must support a common serial communication protocol such as Modbus, DF/1 or even dumb ASCII. Data from your product will transfer to the gateway at serial baud rates (1200-19200).

    Other than time-to-market (typically a week or two), there are few real advantages to this approach and many negatives. Gateways require an additional footprint, they can be costly, they are generally overkill for a simple device and the gateway vendor appears as the AS-Interface device owner. This option is only attractive if you expect low volume requests for AS-Interface connectivity.

  2. Use an AS-Interface PCB

    If your device uses standard signals, an AS-Interface PCB that accepts your signals and places them on the bus is an alternative solution for quick time-to-market projects. Built to your exact footprint and I/O requirements, a custom solution is relatively fast and requires almost none of your resources. Custom solutions offer you the latest in capabilities while giving you absolute control of your development, network presentation and implementation. This approach is great for medium volume applications (i.e. a few hundred units per year). Real Time Automation, Inc. supplies PCBs of this kind. The advantages to this approach are relatively low cost and tight system operation. Disadvantages include the cost of one-time tooling and NRE.

  3. Do-It-Yourself

    The most costly, lengthy and risky approach is to form an internal effort to build it yourself. While this is admittedly what you’d expect to hear from a company whose business is selling custom networking hardware and software, the facts still speak for themselves. Like most bus implementations there are nuances to the AS-Interface specification that are not readily discernable. For example, the specification provides some very ambiguous language describing how to pick the device ID.

Just a Few More Things to Think About Before You Take the Leap

Another important consideration is testing and certification. Do you have the tools and resources to test, troubleshoot and certify your AS-Interface implementation? A key to selecting a vendor to get “AS-Interface in 30 days” is to make sure that your vendor has all the right tools and can assist you with troubleshooting, locating adequate test tools and the certification of your device.

>> You must consider documentation. There are standard documentation formats for network devices. Your customers will expect your products to follow these standards. To get to market in 30 days, documentation issues need to be addressed early in the process.

>>You must consider certification. Many customers simply will not purchase products unless they have passed a certification test. It’s not uncommon for products to be sent back to the lab a second or third time before they finally pass. If RTA does an AS-Interface implementation for your product, you are guaranteed first time success.

>>You must consider maintenance and support. There are keys to success for any new technology. There will be inevitable corrections and revisions to the initial specifications. How you deal with these changes matters a great deal.

Want to learn more or have a project you’d like to discuss with us?