Connect BACnet MS/TP Subordinates to Siemens S7 PLCs

The easiest way to connect BACnet MS/TP Subordinates to Siemens S7 PLCs!

460BMSC

$896.72$1,251.75

SKU: 460BMSC

INCLUDES
PRODUCT FEATURES
DATASHEETS & USERGUIDES

Get BACnet MS/TP Subordinate Data into your Siemens S7 PLC

The 460BMSC moves data between your BACnet MS/TP subordinates to your Siemens S7 PLC.

Best of all, the product is made in the USA, always in stock and comes with 5-year warranty.

How do I use the 460BMSC in my application?

BACnet analog, binary and CSV data segments can be converted to corresponding data
types as your Siemens PLCs and transferred over to them and vice versa.

It’s really that simple. Need to modify your data as it passes from one protocol to the other?
No problem. Each data mapping you apply can be modified with up to three mathematic
functions.

Why Use Real Time Automation as a Gateway Supplier?

While there are certainly other companies offering protocol gateways, there is no one who
provides the level of support and service that you receive from RTA.

When you call, a live person answers the phone. When you talk with sales, you will get
honest answers and recommendations. When you get support, it is from an engineer who
had a hand in the product’s development, and support doesn’t require a ticket or 24-hour
wait.

BACnet MS/TP Manager Features

BACnet/ MS/TP Operation Modes: BACnet MS/TP Manager Initiator
Supported Object Types: Device, Binary, Analog, Multi-State, Character String Value
Supported Service Codes: Read Property-A, Read Property Multiple-A, Write Property-A, Write Property
Multiple-A, Device Dynamic Binding-A
Maximum Connections: 32
Number Read/Write Scan Lines per Device: 200 Total - 100 reads & 100 writes
Scan Line Support: Up to 128 Total Objects

S7 Client Features

PLC Support: S7 300/400/1200/1500
Maximum Number of PLCs Supported: 5
Maximum Number of Inputs per PLC: 150
Maximum Number of Outputs per PLC: 150
Array Support: Yes, for all data types
Supported Data Types: 8Bit Int, 16Bit Int, 32Bit Int, 32Bit Float, Bool and String

What our Customers are Saying

“I challenged a customer to get it working by the time I got back from his break room with a Coke and he indeed had it working when I got back. He then said, "It’s worth twice the price!"”

Eric P. / Kendall Electric

“Everything seems to be working as we imagined. Thanks for the great response time. I did not see any way to save the configuration other than screen shots, but the configuration did not get lost in the update. Thanks again, and you were a pleasure to work with.”

Kevin L. / Extol, Inc.