Connect BACnet MS/TP Subordinates to Serial PLCs

Easily control up to 32 BACnet MS/TP Subordinate devices from a legacy DF1 PLC

460BMDFM

$941.28$1,040.21

SKU: 460BMDFM

INCLUDES
PRODUCT FEATURES
DATASHEETS & USERGUIDES

Control Up To 32 BACnet MS/TP Subordinate Devices from a Serial PLC5, SLC or MicroLogix PLC
You can now control a network of 32 BACnet MS/TP Subordinates from a legacy Allen-Bradley serial PLC. It’s the perfect tool to save legacy PLCs from the scrap pile and control BACnet MS/TP devices directly from the serial port of PLC5s, SLCs and MicroLogix PLCs.

How Do I Use the 460BMDFM in My Application?
For most applications the mapping is very straight forward. PLC data table values (File like N7:200 and F9:1) are mapped directly into the Input and Output assemblies of the cyclic data transfer. Input files from your legacy PLC are passed to the BACnet MS/TP Subordinate as part of the cyclic Input message. Output data received from a BACnet MS/TP Subordinate is written to your legacy PLC data table. You can map up to 100 integers, 50 floating point values and 100 binary values in your PLC directly to the Input and Output assemblies.

No message instructions and no ladder. It really is that simple.

Why Use Real Time Automation as a Gateway Supplier?
The 460BMDFM provides an option to connect BACnet MS/TP Subordinates to serial Allen-Bradley controllers. While there are certainly a number of other companies offering stand alone gateways, there is no one who provides the level of support and service that you receive from RTA.

When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations even if that means recommending someone else’s solution. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24 hour wait. We are unashamed of the fact that we are a smaller company because that means you mean a lot more to us.

Try the RTA difference today and give us a call at 1-800-249-1612 or check out more.

BACnet MS/TP Manager Features

BACnet/ MS/TP Operation Modes: BACnet MS/TP Manager Initiator
Supported Object Types: Device, Binary, Analog, Multi-State, Character String Value
Supported Service Codes: Read Property-A, Read Property Multiple-A, Write Property-A, Write Property
Multiple-A, Device Dynamic Binding-A
Maximum Connections: 32
Number Read/Write Scan Lines per Device: 200 Total - 100 reads & 100 writes
Scan Line Support: Up to 128 Total Objects

DF1 Master Features

Operation Modes: DFM Full Duplex and DFM Half Duplex
PLCs Supported: MicroLogix 1000, SLC 5/03 5/04 5/05, most PLC5s
Maximum number of Devices supported: 1 in Full Duplex Mode, 32 in Half Duplex
Data Type Supported: 100 Integers or 100 Binaries, or 50 floats, 82 character string per scan line
Scan lines: 100 input, 100 output
Physical Connections: RS485 and RS232

What our Customers are Saying

“I challenged a customer to get it working by the time I got back from his break room with a Coke and he indeed had it working when I got back. He then said, "It’s worth twice the price!"”

Eric P. / Kendall Electric

“Everything seems to be working as we imagined. Thanks for the great response time. I did not see any way to save the configuration other than screen shots, but the configuration did not get lost in the update. Thanks again, and you were a pleasure to work with.”

Kevin L. / Extol, Inc.