Connect DeviceNet Slaves to Serial DF1 PLCs

Easily control up to 32 DeviceNet Slave devices from a legacy Allen-Bradley DF1 PLC.

460DMDFM

$963.56$1,040.21

SKU: 460DMDFM

INCLUDES
PRODUCT FEATURES
DATASHEETS & USERGUIDES

Control Up To 32 DeviceNet Slave Devices from a Serial PLC5, SLC or MicroLogix PLC
You now have the capability to efficiently manage a network comprising up to 32 DeviceNet Slaves using a legacy Allen-Bradley serial DF1 PLC. Connecting DeviceNet Slaves to Serial DF1 PLCs not only preserves older PLC models like the PLC5, SLC, and MicroLogix from being rendered obsolete but also empowers them to directly oversee and control DeviceNet devices. It represents a pivotal tool in extending the lifespan and functionality of these venerable PLCs. It offers a cost-effective and practical alternative to costly upgrades or replacements.

How Do I Use the 460DMDFM in My Application?
In most cases, the mapping process is remarkably straightforward. PLC data table values, such as N7:200 and F9:1, are directly transferred into the Input and Output assemblies of the cyclic data exchange for every DeviceNet Slave connection. The 460DMDFM simplifies the integration process significantly, making it accessible even for those with minimal experience in the field.

For more legacy gateway solutions check out our Solutions for Allen-Bradley Legacy PLCs page.

Why Use Real Time Automation as a Gateway Supplier?
While there are certainly other companies offering protocol gateways, there is no one who provides the level of support and service that you receive from Real Time Automation. When you call us, a live person answers the phone. If you talk with our sales team, you will get honest answers and recommendations. And rest assured, all the support you get is from an engineer who had a hand in the product’s development, and support doesn’t need a ticket or 24-hour wait. We get back to you as soon as possible. It’s an RTA promise. Try the RTA difference today.

DeviceNet Master Features

DeviceNet Operation Modes: UCMM Client, Group 2 Client, Group 2 only Client
Implicit Message Support: Polled only, Assembly Object
Maximum DeviceNet Slave Devices: 32
Data per Slave: 0-400 Bytes in each direction
Supported Data Types: BIT8, BIT16, BIT32, INT8, INT16, INT32, INT64, UINT8, UINT16, UINT32, UINT64, Float, Double

DF1 Master Features

Operation Modes: DFM Full Duplex and DFM Half Duplex
PLCs Supported: MicroLogix 1000, SLC 5/03 5/04 5/05, most PLC5s
Maximum number of Devices supported: 1 in Full Duplex Mode, 32 in Half Duplex
Data Type Supported: 100 Integers or 100 Binaries, or 50 floats, 82 character string per scan line
Scan lines: 100 input, 100 output
Physical Connections: RS485 and RS232