Connect DeviceNet Master to BACnet MS/TP

Easily connect a DeviceNet Master Device to a BACnet MS/TP Master

SKU: 460DSBMS

460DSBMS

Price$865.00

Clear

Product Description

Get Your DeviceNet Master Device Connected Directly to Your Building Automation System
The 460DSBMS moves data between a DeviceNet Master and a BACnet MS/TP Building Automation System. With the 460DSBMS you are making a direct connection between DeviceNet data and BACnet MS/TP Binary and Analog objects.

How Do You Map the Data?
Up to 240 bytes of DeviceNet data will be mapped into your BACnet MS/TP Master. Data will be assigned a type of BIT8, BIT16, BIT32, INT8, INT16, INT32, INT64, UINT8, UINT16, UINT32, UINT64, Float, or Double and be mapped into your BACnet MS/TP Building Automation System as Binary and Analog BACnet MS/TP objects. When writing from your BACnet MS/TP Master to your DeviceNet Master, up to 1200 analog and 1600 binary and 50 Character String BACnet MS/TP objects will be viewed as DeviceNet data.

It’s really that simple. Need to modify your data as it passes from one protocol to the other? No problem. Each data mapping you apply can be modified with up to 3 mathematic functions. Add 4 to a value, multiply by 4 and divide by 10 with ease.

Why Use Real Time Automation as a Gateway Supplier?
The 460DSBMS provides an option to access DeviceNet Master data without having to upgrade your established BACnet MS/TP system. While there are certainly a number of other companies offering stand alone gateways, there is no one who provides the level of support and service that you receive from RTA.

When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations even if that means recommending someone else’s solution. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24 hour wait. We are unashamed of the fact that we are a smaller company because that means you mean a lot more to us.

  • Manual
  • 5 Year Hardware Warranty
  • IPSetup software — Automatically locates RTA Gateway on the network
  • Unlimited Firmware Feature Upgrades for Life
  • CAT5 Cross over cable for direct connection to PC during programming
  • Complete, Unlimited Access to our Industry Leading Support Staff

DeviceNet Slave Features

DeviceNet Operation Modes
DeviceNet Slave

Supported Data Types
Int8, int16, int32, int64, uint8, uint16, uint32, uint61, float, double float, binary8, binary16, binary32

Maximum Connections
1

Maximum Input Size
240 Bytes in up to 15 Data Groups

Maximum Output Size
240 Bytes in up to 15 Data Groups

BACnet MS/TP Slave Features

BACnet/ MS/TP Operation Modes
BACnet MS/TP Master Responder

Supported Object Types
Device, Binary I/O, Analog I/O, Character String Value

Supported Service Codes
Read & Read Multiple-B, Write & Write Multiple-B, COV & COV unsolicited-B, Device Dynamic Binding, Dynamic Object Binding-B, Device Communication Control-B

Maximum Connections
1

Analog Objects
Supported 1200 Input and 1200 Output

Binary Objects
Supported 1600 Input and 1600 Output

Gateway Security

You can configure up to 9 different users access to diagnostic and configuration screens.

Alarming

Set <, <=, >=, >, ==, !=, and Change-of-State rules on any data moving through the gateway. If alarm rule is triggered an email notification can be sent.

Translation Table

Allows for data manipulation during protocol translation. Scaling and other data format changes can occur in the gateway.

Status and Counters

Protocol specific status, counters and error messages are accessible within the gateways diagnostics page. They can also be delivered to a connected device.

Diagnostic Logging Page

Allows users to see and log start up sequences, protocol specific messages & error messages.

 

460DSBMS-N34
DATASHEET  USERGUIDE