BACnet/IP Servers to Allen-Bradley PLC Gateway
The easiest way to connect BACnet/IP server devices to Allen-Bradley PLCs. The 460ETCBC gateway allows you to connect up to 32 BACnet/IP servers to up to 5 Allen-Bradley ControlLogix, CompactLogix, FlexLogix, MicroLogix, SLC 5/05 or PLC-5E PLCs.
460ETCBC
Price range: $896.72 through $1,035.00
Move BACnet Data Directly to Your Allen-Bradley PLC Data Table
The 460ETCBC moves data between up to 32 BACnet/IP server devices and up to 5 Allen-Bradley PLCs over an Ethernet connection. As a result, you can easily integrate BACnet/IP-enabled boilers, lighting systems, security systems and other devices to your industrial automation network.
How Does the 460ETCBC Gateway Move BACnet Data In and Out of the PLC?
To transfer data between BACnet/IP servers and Allen-Bradley PLCs, the PLCs must allocate two areas of tags or register blocks:
- A set of user-defined write-only tags or register blocks to accept BACnet/IP data
- A set of read-only tags or register blocks to send data to your BACnet/IP devices
Using a browser-based interface, you directly map BACnet/IP Analog and Binary data into read and write locations in the data table of your Allen-Bradley PLC.
It’s really that simple. With the 460ETCBC, you are making a direct connection between BACnet/IP objects and user-defined tags or registers. There is no polling from the PLC or scan lists to arrange.
Not exactly what you were looking for? Real Time Automation offers a full line of BACnet/IP gateways, BACnet MS/TP gateways and Allen-Bradley solutions
Why Trust Real Time Automation As Your Protocol Partner?
While there are certainly other companies offering protocol gateways, no one provides the level of support and service that you receive from Real Time Automation.
- Total protocol lifecycle support
- Talk to a live person from our Wisconsin-based headquarters every time you call
- Receive honest answers and recommendations from our sales team
- Get live Enginerd support that provides timely issue resolution without opening tickets or 24-hour wait times
460ETCBC Frequently Asked Questions
The 460ETCBC gateway can be connected to up to 5 Allen-Bradley ControlLogix, CompactLogix, FlexLogix, MicroLogix, SLC 5/05 or PLC-5E PLCs.
The 460ETCBC is available in a variety of platform options. Use the platform comparison table to find the platform that matches your application.
Purchases can be made through authorized RTA distributors or directly from Real Time Automation. Orders may be submitted by emailing a purchase order to orders@rtautomation.com or by purchasing directly on the RTA website with a credit card.
The 460ETCBC is delivered with a 5-year warranty.
RTA offers multiple support options. Live Enginerd support is available from 8am to 5pm CST. Call 800-249-1612, email support@rtautomation.com or visit the support page.
EtherNet/IP Tag Client Features
PLC Support: ControlLogix, CompactLogix, FlexLogix, MicroLogix, SLC’s and PLC5E’sMaximum Number of PLCs Supported: 5
Maximum Number Read Tags or Registers Supported: 150 per PLC
Maximum Number Write Tags or Registers Supported: 150 per PLC
Array Support: Yes, for all data types except strings
Supported Data Types: ControlLogix / CompactLogix / FlexLogix: Bit, 32 Bit Array, SINT, INT, REAL, STRING, DINT, MicroLogix / SLC / PLC5E: 16 Bit Array, INT, REAL, STRING
BACnet/IP Client Features
BACnet/IP Operation Modes: BACnet/IP ClientSupported Object Types: Device, BI/BO/BV, AI/AO/AV, MI/MO/MV, Character String Value
Supported Service Codes: Read Property-A, Read Property Multiple-A, Write Property-A, Write Property Multiple-A, Device Dynamic Binding-A
Maximum Connections: 32
Number Read/Write Scan Lines per Device: 200 Total - 100 reads and 100 writes
Scan Line Support: Up to 128 Objects