Connect Modbus RTU Slaves to BACnet MS/TP

Connect Modbus RTU Slaves to BACnet MS/TP Responders

SKU: 460MMBM

460MMBM

Price$750.00$875.00

Clear

Product Description

Connect Modbus RTU Slaves to BACnet MS/TP Devices
The 460MMBM moves data between a network of up to 32 Modbus RTU Slaves and up to 32 BACnet MS/TP devices.

With the 460MMBM you’re mapping Modbus coil and register data directly to BACnet MS/TP as binary and analog values.

How Do I Use 460MMBM-N34 in My Application?
Modbus register data is mapped to BACnet analog objects and Modbus coil data is mapped to binary objects. The only additional piece required for BACnet is adding meta data which is nothing more than an ASCII description of each object.

It really is that simple.

Why Use Real Time Automation as a Gateway Supplier?
While there are certainly other companies offering protocol gateways, there is no one who provides the level of support and service that you receive from RTA. When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24-hour wait.

Try the RTA difference today.

  • Manual
  • 3’ power cable with Flying leads
  • 5 Year Hardware Warranty
  • IPSetup software — Automatically locates RTA Gateway on the network
  • Unlimited Firmware Feature Upgrades for Life
  • CAT5 Cross over cable for direct connection to PC during programming
  • Complete, Unlimited Access to our Industry Leading Support Staff

Modbus RTU Master Features

Modbus Operation Modes
Modbus RTU Master

Function Codes Supported

1,2,3,4,5,6,15 & 16

Swapping
Byte and Word Swapping

Maximum Modbus RTU Slave Devices
32

Number Read/Write Scan Lines per RTU Slave Device
200 Total - 100 reads & 100 writes

Scan Line Support
Up to 125 Registers or 512 Coils

BACnet MS/TP Master Features

BACnet/ MS/TP Operation Modes
BACnet MS/TP Master Initiator

Supported Object Types
Device, Binary, Analog, Multi-State, Character String Value

Supported Service Codes
Read Property-A, Read Property Multiple-A, Write Property-A, Write Property
Multiple-A, Device Dynamic Binding-A

Maximum Connections
32

Number Read/Write Scan Lines per Device
200 Total - 100 reads & 100 writes

Scan Line Support
Up to 128 Total Objects

Gateway Security

You can configure up to 9 different users access to diagnostic and configuration screens.

Alarming

Set <, <=, >=, >, ==, !=, and Change-of-State rules on any data moving through the gateway. If alarm rule is triggered an email notification can be sent.

Translation Table

Allows for data manipulation during protocol translation. Scaling and other data format changes can occur in the gateway.

Status and Counters

Protocol specific status, counters and error messages are accessible within the gateways diagnostics page. They can also be delivered to a connected device.

Diagnostic Logging Page

Allows users to see and log start up sequences, protocol specific messages & error messages.

 

460MMBM-N34
DATASHEET  USERGUIDE
460MMBM-N700
DATASHEET  USERGUIDE
460MMBM-NNA4
DATASHEET  USERGUIDE
Click here to download our Gateway Comparison PDF