OPC UA Connection to DF1 Protocol

Connect up to three OPC Clients to up to 32 DF1 Slaves

460USDFM

$896.72$1,251.75

SKU: 460USDFM

INCLUDES
PRODUCT FEATURES
DATASHEETS & USERGUIDES

Connect your OPC UA clients to DF1 slave device

The 460USDFM moves data between OPC UA clients and DF1 slave devices. Allowing you to easily log data and leverage for populating data in dashboards. Best of all, the product is made in the USA and comes with 5-year warranty.

How Do I Use the 460USDFM in My Application?

For most applications, the mapping is very straightforward. OPC UA data is mapped to files in the PLCs data tables. Those values are then mapped to mating file locations in the DF1 devices like N7:200 or F9:1. SSL transport layer security protects the data moving from your operations network to the cloud.

Why Use Real Time Automation as a Gateway Supplier?

While there are certainly other companies offering protocol gateways, there is no one who provides the level of support and service that you receive from RTA.

When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24-hour wait.

OPC UA Server Features

Operation Mode: opc.tcp/binary with no Security
Simultaneous Connections Supported: 3
Max Number of Input Nodes per Node Type: 200
Max Number of Output Nodes per Node Type: 200
Array Support: Boolean, Integer, Unsigned Int and Float
Profiles Supported: UA 1.03 Micro Embedded Server and Data Access

DF1 Master Features

Operation Modes: DFM Full Duplex and DFM Half Duplex
PLCs Supported: MicroLogix 1000, SLC 5/03 5/04 5/05, most PLC5s
Maximum number of Devices supported: 1 in Full Duplex Mode, 32 in Half Duplex
Data Type Supported: 100 Integers or 100 Binaries, or 50 floats, 82 character string per scan line
Scan lines: 100 input, 100 output
Physical Connections: RS485 and RS232

What our Customers are Saying

“I challenged a customer to get it working by the time I got back from his break room with a Coke and he indeed had it working when I got back. He then said, "It’s worth twice the price!"”

Eric P. / Kendall Electric

“Everything seems to be working as we imagined. Thanks for the great response time. I did not see any way to save the configuration other than screen shots, but the configuration did not get lost in the update. Thanks again, and you were a pleasure to work with.”

Kevin L. / Extol, Inc.