Connect Modbus RTU Servers to an Allen-Bradley PLC

The 460ETCMM easily connects up to 32 Modbus RTU server devices to your Allen-Bradley PLC. Integrating the 460ETCMM helps expand your system’s connectivity and functionality to suit your needs.

460ETCMM

$896.72$1,251.75

SKU: 460ETCMM

INCLUDES
PRODUCT FEATURES
DATASHEETS & USERGUIDES

Connect Your Modbus RTU Server Devices Directly to Your Allen-Bradley PLC Data Table

The 460ETCMM connects 32 Modbus RTU devices to five Allen-Bradley PLCs. It can help integrate legacy or low-cost Modbus RTU controllers into an Allen-Bradley architecture. As a result, you’ll save your Modbus RTU devices from the scrap pile for years to come.

How Does the Data Move In and Out of the PLC?

In your Allen-Bradley PLC, designate one area for custom write-only tags or registers receiving data from Modbus RTU devices. In the other area, you fill it with read-only tags or register blocks to transmit data to your Modbus RTU devices. You directly map Modbus RTU register and coil data into read and write locations in the data table of your Allen-Bradley PLC.

Do you need to modify your data as it passes from one protocol to the other? No problem. Each data mapping you apply can be modified with up to three mathematic functions. Add 4 to a value, multiply by 4 and divide by 10 with ease.

Configure Modbus to Allen-Bradley Gateways using templates from RTA

For more gateway solutions check out our Solutions for Allen-Bradley PLCs page.

Why Use Real Time Automation as a Gateway Supplier?

The 460ETCMM provides an option to access Modbus RTU server devices without having to upgrade your PLC or get an expensive in rack solution. While there are certainly other companies offering protocol gateways, there is no one who provides the level of support and service that you receive from Real Time Automation. When you call us, a live person answers the phone. If you talk with our sales team, you will get honest answers and recommendations. And rest assured, all the support you get is from an engineer who had a hand in the product’s development, and support doesn’t need a ticket or 24-hour wait. We get back to you as soon as possible. It’s an RTA promise.

Modbus RTU Client Features

Modbus Operation Modes: Modbus RTU Client
Function Codes Supported: 1, 2, 3, 4, 5, 6, 15 & 16
Swapping: Byte and Word Swapping
Maximum Modbus RTU Client Devices: 32
Number Read/Write Scan Lines per RTU Server Device: 200 Total - 100 reads & 100 writes
Scan Line Support: Up to 125 Registers or 512 Coils

EtherNet/IP Tag Client Features

PLC Support: ControlLogix, CompactLogix, FlexLogix, MicroLogix, SLC’s and PLC5E’s
Maximum Number of PLCs Supported: 5
Maximum Number Read Tags or Registers Supported: 150 per PLC
Maximum Number Write Tags or Registers Supported: 150 per PLC
Array Support: Yes, for all data types except strings
Supported Data Types: ControlLogix / CompactLogix / FlexLogix: Bit, 32 Bit Array, SINT, INT, REAL, STRING, DINT, MicroLogix / SLC / PLC5E: 16 Bit Array, INT, REAL, STRING