Connect BACnet MS/TP Devices to Serial Allen-Bradley PLCs

Connects up to 32 BACnet MS/TP slaves with as many as 32 DH+ devices

460BMDHM

$1,495.00$1,510.75

SKU: 460BMDHM

INCLUDES
PRODUCT FEATURES
DATASHEETS & USERGUIDES

Control up to 32 BACnet MS/TP Devices from a Serial PLC5 or SLC PLC

You can now control a network of 32 BACnet MS/TP devices from a legacy Allen-Bradley serial PLC. It’s the perfect tool to save legacy PLCs from the scrap pile and control BACnet MS/TP devices directly from the serial port of PLC5s, SLCs, and MicroLogix™. You can now extend the function of the legacy PLCs your already have.

How Do I Use the 460BMDHM-D2E in My Application?

PLC data table values (File like N7:200 and F9:1) are mapped directly into analog and binary values. Input files from your legacy PLC are passed to the BACnet MS/TP devices. Output data received from BACnet MS/TP is written to your legacy PLC data table. No message instructions and no ladder. It really is that simple.

Why Use Real Time Automation as a Gateway Supplier?

While there are certainly other companies offering protocol gateways, there is no one who provides the level of support and service that you receive from RTA.
When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24-hour wait.

DH+ Features

Operation Mode: DH+ Master
PLCs Supported: 5/04, PLC5
Maximum Devices Supported: 32
Scan Lines: 100 input / 100 output
Supported Data Types: 100 Integers or 100 Binaries, or 50 floats, 82 character string per Scan line

BACnet MS/TP Manager Features

BACnet/ MS/TP Operation Modes: BACnet MS/TP Manager Initiator
Supported Object Types: Device, Binary, Analog, Multi-State, Character String Value
Supported Service Codes: Read Property-A, Read Property Multiple-A, Write Property-A, Write Property
Multiple-A, Device Dynamic Binding-A
Maximum Connections: 32
Number Read/Write Scan Lines per Device: 200 Total - 100 reads & 100 writes
Scan Line Support: Up to 128 Total Objects