Get Your Serial DF1 PLC Data into a BACnet MS/TP Network

Easily map your legacy PLC data into a BACnet MS/TP Manager

460BMSDFM

$941.28$1,040.21

SKU: 460BMSDFM

INCLUDES
PRODUCT FEATURES
DATASHEETS & USERGUIDES

Map Your Legacy PLC Data Tables Into a BACnet MS/TP Manager
You can now make your legacy serial PLCs look like a BACnet MS/TP device! Any of your old, serial PLCs like the PLC5, SLC, or MicroLogix can now provide data to a BACnet/ MS/TP building automation system.

It’s the perfect tool to keep those old legacy PLCs from the scrap pile.

How Do I Use the 460BMSDFM in My Application?
For most applications, the mapping is very straight forward. PLC data table values like N7:200 and F9:1 are mapped directly to BACnet Analog and Binary values.

No message instructions and no ladder logic changes are required to monitor the PLC data on BACnet MS/TP.

It really is that simple.

Why Use Real Time Automation as a Gateway Supplier?
While there are certainly a number of other companies offering gateways, there is no one who provides the level of support and service that you receive from RTA.

When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24-hour wait.

Try the RTA difference today.

BACnet MS/TP Slave Features

BACnet/ MS/TP Operation Modes: BACnet MS/TP Master Responder
Supported Object Types: Device, Binary I/O, Analog I/O, Character String Value
Supported Service Codes: Read & Read Multiple-B, Write & Write Multiple-B, COV & COV unsolicited-B, Device Dynamic Binding, Dynamic Object Binding-B, Device Communication Control-B
Maximum Connections: 1
Analog Objects: Supported 1200 Input and 1200 Output
Binary Objects: Supported 1600 Input and 1600 Output

DF1 Master Features

Operation Modes: DFM Full Duplex and DFM Half Duplex
PLCs Supported: MicroLogix 1000, SLC 5/03 5/04 5/05, most PLC5s
Maximum number of Devices supported: 1 in Full Duplex Mode, 32 in Half Duplex
Data Type Supported: 100 Integers or 100 Binaries, or 50 floats, 82 character string per scan line
Scan lines: 100 input, 100 output
Physical Connections: RS485 and RS232

What our Customers are Saying

“I challenged a customer to get it working by the time I got back from his break room with a Coke and he indeed had it working when I got back. He then said, "It’s worth twice the price!"”

Eric P. / Kendall Electric

“Everything seems to be working as we imagined. Thanks for the great response time. I did not see any way to save the configuration other than screen shots, but the configuration did not get lost in the update. Thanks again, and you were a pleasure to work with.”