Connect Your BACnet MS/TP Devices to a Siemens S7 PLC

The easiest way to get your BACnet MS/TP system connected directly to the data table of your Siemens S7 PLC.

460BMSSC

$896.72$1,251.75

SKU: 460BMSSC

INCLUDES
PRODUCT FEATURES
DATASHEETS & USERGUIDES

Get Your BACnet MS/TP System Connected Directly to the Data Table of your Siemens S7 PLC

The 460BMSSC connects a BACnet MS/TP system and up to 5 Siemens S7 PLC.

Best of all the product is Made in the USA, is always in stock and comes with 5-year warranty.

How do I use 460BMSSC in my application?

You allocate two memory blocks in your Siemens S7 PLC. One area is a user-defined set of Output addresses sending data to your BACnet MS/TP Master. The other is Input only data receiving data from your BACnet MS/TP Master.

It’s really that simple. Need to modify your data as it passes from one protocol to the other? No problem. Each data mapping you apply can be modified with up to 3 mathematic functions. Add 4 to a value, multiply by 4 and divide by 10 with ease.

Why Use Real Time Automation as a Gateway Supplier?

While there are certainly other companies offering protocol gateways, there is no one who provides the level of support and service that you receive from RTA.

When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24-hour wait.

BACnet MS/TP Slave Features

BACnet/ MS/TP Operation Modes: BACnet MS/TP Master Responder
Supported Object Types: Device, Binary I/O, Analog I/O, Character String Value
Supported Service Codes: Read & Read Multiple-B, Write & Write Multiple-B, COV & COV unsolicited-B, Device Dynamic Binding, Dynamic Object Binding-B, Device Communication Control-B
Maximum Connections: 1
Analog Objects: Supported 1200 Input and 1200 Output
Binary Objects: Supported 1600 Input and 1600 Output

S7 Client Features

PLC Support: S7 300/400/1200/1500
Maximum Number of PLCs Supported: 5
Maximum Number of Inputs per PLC: 150
Maximum Number of Outputs per PLC: 150
Array Support: Yes, for all data types
Supported Data Types: 8Bit Int, 16Bit Int, 32Bit Int, 32Bit Float, Bool and String

What our Customers are Saying

“I challenged a customer to get it working by the time I got back from his break room with a Coke and he indeed had it working when I got back. He then said, "It’s worth twice the price!"”

Eric P. / Kendall Electric

“Everything seems to be working as we imagined. Thanks for the great response time. I did not see any way to save the configuration other than screen shots, but the configuration did not get lost in the update. Thanks again, and you were a pleasure to work with.”

Kevin L. / Extol, Inc.