Connect BACnet MS/TP Subordinates to DeviceNet

Easily Connect BACnet MS/TP devices to a DeviceNet Master

460DSBM

$963.56$979.31

SKU: 460DSBM

INCLUDES
PRODUCT FEATURES
DATASHEETS & USERGUIDES

Get Your BACnet MS/TP Subordinates Connected Directly to Your DeviceNet Master
The 460DSBM moves data between up to 32 BACnet MS/TP Subordinates and a DeviceNet Master. With the 460DSBM you are making a direct connection between DeviceNet data and BACnet MS/TP Binary and Analog objects.

How Do You Map the Data?
Up to 240 bytes of DeviceNet data will be mapped to your BACnet MS/TP Subordinates as BACnet MS/TP data. When writing from your BACnet MS/TP Subordinates to your DeviceNet Master, Analog and Binary BACnet MS/TP objects will be viewed as DeviceNet data.

It’s really that simple. Need to modify your data as it passes from one protocol to the other? No problem. Each data mapping you apply can be modified with up to 3 mathematic functions. Add 4 to a value, multiply by 4 and divide by 10 with ease.

Why use Real Time Automation as a Gateway Supplier?
The 460DSBM provides an option to access BACnet MS/TP Subordinate data in your DeviceNet Master without having to upgrade your established system. While there are certainly a number of other companies offering stand alone gateways, there is no one who provides the level of support and service that you receive from RTA.

When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations even if that means recommending someone else’s solution. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24 hour wait. We are unashamed of the fact that we are a smaller company because that means you mean a lot more to us.

BACnet MS/TP Manager Features

BACnet/ MS/TP Operation Modes: BACnet MS/TP Manager Initiator
Supported Object Types: Device, Binary, Analog, Multi-State, Character String Value
Supported Service Codes: Read Property-A, Read Property Multiple-A, Write Property-A, Write Property
Multiple-A, Device Dynamic Binding-A
Maximum Connections: 32
Number Read/Write Scan Lines per Device: 200 Total - 100 reads & 100 writes
Scan Line Support: Up to 128 Total Objects

DeviceNet Slave Features

DeviceNet Operation Modes: DeviceNet Slave
Supported Data Types: Int8, int16, int32, int64, uint8, uint16, uint32, uint61, float, double float, binary8, binary16, binary32
Maximum Connections: 1
Maximum Input Size: 240 Bytes in up to 15 Data Groups
Maximum Output Size: 240 Bytes in up to 15 Data Groups

What our Customers are Saying

“I challenged a customer to get it working by the time I got back from his break room with a Coke and he indeed had it working when I got back. He then said, "It’s worth twice the price!"”

Eric P. / Kendall Electric

“Everything seems to be working as we imagined. Thanks for the great response time. I did not see any way to save the configuration other than screen shots, but the configuration did not get lost in the update. Thanks again, and you were a pleasure to work with.”