Connect EtherNet/IP Devices to a Modbus TCP/IP Controller

Connect up to 32 EtherNet/IP Adapters to a Modbus TCP/IP Client

SKU: 460ECMS

460ECMS

Price$805.00$976.25

Clear

Product Description

The Smart Way To Move EtherNet/IP Adapter Data To a Modbus TCP Controller
The 460ECMS moves data between up to 32 EtherNet/IP Adapters and a Modbus TCP/IP Client. Modbus is still the catch all protocol. It’s dirt simple and been around forever which means there is huge base of users and legacy systems supporting Modbus. With the 460ECMS you now have a great tool to integrate newer EtherNet/IP devices into these systems.

With the 460ECMS you have a device that you can quickly deploy and easily configure to access and integrate these EtherNet/IP devices into your Modbus TCP network.

How Does the 460ECMS Work?
Up to 496 bytes of Ethernet/IP data can be mapped in each direction from up to 32 devices. Once the data is manually entered for each EtherNet/IP connection the data is automatically mapped by the gateway to Modbus TCP/IP.

It really is that simple.

Why Use Real Time Automation as a Gateway Supplier?
The 460ECMS provides an option to connect EtherNet/IP Adapter devices to your Modbus TCP/IP network. While there are certainly a number of other companies offering stand alone gateways, there is no one who provides the level of support and service that you receive from RTA.

When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations even if that means recommending someone else’s solution. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24 hour wait. We are unashamed of the fact that we are a smaller company because that means you mean a lot more to us.

Try the RTA difference today and give us a call at 1-800-249-1612

  • Manual
  • 3’ power cable with Flying leads
  • 5 Year Hardware Warranty
  • IPSetup software — Automatically locates RTA Gateway on the network
  • Unlimited Firmware Feature Upgrades for Life
  • CAT5 Cross over cable for direct connection to PC during programming
  • Complete, Unlimited Access to our Industry Leading Support Staff

Ethernet/IP Scanner Features

Operation Modes
Class 1 I/O Scanner (minimal Adapter is required and supported)

Message Support
Implicit Class 1 Cyclic I/O, Explicit not supported.

Data Types
BIT8,16 & 32; INT8, 16, 32 & 64; UINT8,16, 32 & 64; Float & Double

Maximum EtherNet/IP Adapter Devices
32

Max Data Per Adapter Connection
Up to 496 bytes in each direction

Modbus TCP/IP Server Features

Modbus Operation Modes
Modbus TCP/IP Server

Function Codes Supported
1,2,3,4,5,6, 7,15 & 16

Swapping
Byte and Word Swapping

Maximum Modbus TCP/IP Client Connections
1

Contiguous Data Areas
200 Total - 100 reads & 100 writes

Data Area Limits
500 Contiguous Coils or 500 Contiguous Registers

Gateway Security

You can configure up to 9 different users access to diagnostic and configuration screens.

Alarming

Set <, <=, >=, >, ==, !=, and Change-of-State rules on any data moving through the gateway. If alarm rule is triggered an email notification can be sent.

Translation Table

Allows for data manipulation during protocol translation. Scaling and other data format changes can occur in the gateway.

Status and Counters

Protocol specific status, counters and error messages are accessible within the gateways diagnostics page. They can also be delivered to a connected device.

Diagnostic Logging Page

Allows users to see and log start up sequences, protocol specific messages & error messages.

 

460ECMS-N2EW
DATASHEET  USERGUIDE
460ECMS-N2E
DATASHEET  USERGUIDE
460ECMS-N34
DATASHEET  USERGUIDE
460ECMS-N700
DATASHEET  USERGUIDE
460ECMS-NNA1
DATASHEET  USERGUIDE
460ECMS-NNA4
DATASHEET  USERGUIDE
Click here to download our Gateway Comparison PDF