Connect EtherNet/IP Devices to a Modbus TCP/IP Controller

Connect up to 32 EtherNet/IP Adapters to a Modbus TCP/IP Client

460ECMS

$896.72$1,251.75

SKU: 460ECMS

INCLUDES
PRODUCT FEATURES
DATASHEETS & USERGUIDES

The Smart Way To Move EtherNet/IP Adapter Data To a Modbus TCP Controller

The 460ECMS moves data between up to 32 EtherNet/IP Adapters and a Modbus TCP/IP Client. Modbus is still the catch all protocol. It’s dirt simple and been around forever which means there is huge base of users and legacy systems supporting Modbus. With the 460ECMS you now have a great tool to integrate newer EtherNet/IP devices into these systems.

With the 460ECMS you have a device that you can quickly deploy and easily configure to access and integrate these EtherNet/IP devices into your Modbus TCP network.

How Does the 460ECMS Work?

Up to 496 bytes of Ethernet/IP data can be mapped in each direction from up to 32 devices. Once the data is manually entered for each EtherNet/IP connection the data is automatically mapped by the gateway to Modbus TCP/IP.

It really is that simple.

Why Use Real Time Automation as a Gateway Supplier?

The 460ECMS provides an option to connect EtherNet/IP Adapter devices to your Modbus TCP/IP network. While there are certainly a number of other companies offering stand alone gateways, there is no one who provides the level of support and service that you receive from RTA.

When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations even if that means recommending someone else’s solution. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24 hour wait. We are unashamed of the fact that we are a smaller company because that means you mean a lot more to us.

Try the RTA difference today and give us a call at 1-800-249-1612

Ethernet/IP Scanner Features

Operation Modes: Class 1 I/O Scanner (minimal Adapter is required and supported)
Message Support: Implicit Class 1 Cyclic I/O, Explicit not supported
Data Types: BIT8,16 & 32; INT8, 16, 32 & 64; UINT8,16, 32 & 64; Float & Double
Maximum EtherNet/IP Adapter Devices: 32
Max Data Per Adapter Connection: Up to 496 bytes in each direction

Modbus TCP/IP Server Features

Modbus Operation Modes: Modbus TCP/IP Server
Function Codes Supported: 1, 2, 3, 4, 5, 6, 7, 15 & 16
Swapping: Byte and Word Swapping
Maximum Modbus TCP/IP Client Connections: 10
Contiguous Data Areas: 200 Total - 100 reads & 100 writes
Data Area Limits: 500 Contiguous Coils or 500 Contiguous Registers