Modbus TCP/IP Client to Siemens S7 PLC Protocol Gateway
The easiest way to connect a Modbus TCP/IP client device to Siemens S7 PLCs. The 460MSSC protocol gateway allows you to connect a Modbus TCP client device to up to five Siemens S7-300, S7-400, S7-1200 and S7-1500 PLCs.
460MSSC
Price range: $896.72 through $1,035.00
Connect Your Modbus TCP/IP Client Device Directly to Your Siemens S7 PLC Data Table

The 460MSSC connects a Modbus TCP/IP client device to up to five different Siemens S7 PLCs, helping you integrate Modbus TCP-based controllers and supervisory systems into a Siemens architecture without writing custom logic or downloading software.
How Does the 460MSSC Gateway Move Data In and Out of PLC?
In your Siemens S7 PLC, you allocate two data areas:
- A user-defined set of output addresses for sending data to your Modbus TCP client device
- A user-defined set of input-only addresses for receiving data from your Modbus TCP client device
Using a browser-based interface, you directly map Modbus TCP client register and coil data into the designated Input (I), Output (Q) and Data Blocks (DB) within the data table of your Siemens S7 PLC.
Need to modify your data as it passes from one protocol to the other? No problem. Modify each data mapping with up to three mathematical functions.
It’s really that simple.
Not exactly what you were looking for? Real Time Automation offers a full line of Siemens S7 protocol gateways.
Why Trust Real Time Automation As Your Protocol Partner?
While there are certainly other companies offering protocol gateways, no one provides the level of support and service that you receive from Real Time Automation.
- Total protocol lifecycle support
- Talk to a live person from our Wisconsin-based headquarters every time you call
- Receive honest answers and recommendations from our sales team
- Get live Enginerd support that provides timely issue resolution without opening tickets or 24-hour wait times
460MSSC Frequently Asked Questions
The 460MSSC gateway can be connected to any Siemens S7-300, S7-400, S7-1200 or S7-1500 PLC.
The 460MSSC is available in a variety of platform options to meet your unique application needs. Use the platform comparison table to determine the right platform for you.
Purchases can be made through authorized RTA distributors or directly from Real Time Automation. Orders may be submitted by emailing a purchase order to orders@rtautomation.com or by purchasing directly on the RTA website with a credit card.
The 460MSSC is delivered with a 5-year warranty.
RTA offers multiple support options. Live Enginerd support is available from 8am to 5pm CST. Call 800-249-1612, email support@rtautomation.com or visit the support page.
Modbus TCP/IP Server Features
Modbus Operation Modes: Modbus TCP/IP ServerFunction Codes Supported: 1, 2, 3, 4, 5, 6, 7, 15 & 16
Swapping: Byte and Word Swapping
Maximum Modbus TCP/IP Client Connections: 10
Contiguous Data Areas: 200 Total - 100 reads & 100 writes
Data Area Limits: 500 Contiguous Coils or 500 Contiguous Registers
S7 Client Features
PLC Support: S7 300/400/1200/1500Maximum Number of PLCs Supported: 5
Maximum Number of Inputs per PLC: 150
Maximum Number of Outputs per PLC: 150
Array Support: Yes, for all data types
Supported Data Types: 8Bit Int, 16Bit Int, 32Bit Int, 32Bit Float, Bool and String