Connect BACnet MS/TP Devices to Profinet IO

Connects a PROFINET IO Controller with up to 32 BACnet MS/TP Subordinates

460PSBM

$896.72$1,251.75

SKU: 460PSBM

INCLUDES
PRODUCT FEATURES
DATASHEETS & USERGUIDES

Get Your BACnet MS/TP Devices Connected to a Profinet IO Controller
The 460PSBM moves data between a network of up to 32 BACnet MS/TP devices and a Profinet IO Controller. With the 460PSBM you are making a direct connection between Profinet IO data and your BACnet MS/TP devices.

How Do I Use the 460PSBM in My Application?
BACnet MS/TP data will be mapped into 10 Profinet IO slots. Each slot will be assigned a type of Int8, int16, int32, int64, Uint8, Uint16, Uint32, Uint64, float, double, binary8, binary16, binary32, or Short String. The slot can consist of up to 128 bytes of data from your BACnet MS/TP device that your Profinet IO Controller will view as Profinet data. When writing from your Profinet IO Controller, Profinet IO data will be presented to your BACnet MS/TP devices as BACnet MS/TP data.

It’s really that simple. Need to modify your data as it passes from one protocol to the other? No problem. Each data mapping you apply can be modified with up to 3 mathematic functions. Add 4 to a value, multiply by 4 and divide by 10 with ease.

Why Use Real Time Automation as a Gateway Supplier?
While there are certainly other companies offering protocol gateways, there is no one who provides the level of support and service that you receive from RTA.

When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24-hour wait.

Try the RTA difference today.

Profinet IO Server Features

Maximum Number of Slots: 10 Slots in, 10 Slots out
Slot Size: 8, 16, 32, 64 or 128 Bytes
Each Slot Can be Defined for a Single Data Type of: Int8, int16, int32, int64, UInt8, Uint16, Uint32, Uint64, float, double, binary8, binary16 or binary32
Total Data Supported: 1280 Bytes
Maximum Profinet IO Controller Connections: 1

BACnet MS/TP Manager Features

BACnet/ MS/TP Operation Modes: BACnet MS/TP Manager Initiator
Supported Object Types: Device, Binary, Analog, Multi-State, Character String Value
Supported Service Codes: Read Property-A, Read Property Multiple-A, Write Property-A, Write Property
Multiple-A, Device Dynamic Binding-A
Maximum Connections: 32
Number Read/Write Scan Lines per Device: 200 Total - 100 reads & 100 writes
Scan Line Support: Up to 128 Total Objects

What our Customers are Saying

“I challenged a customer to get it working by the time I got back from his break room with a Coke and he indeed had it working when I got back. He then said, "It’s worth twice the price!"”

Eric P. / Kendall Electric

“Everything seems to be working as we imagined. Thanks for the great response time. I did not see any way to save the configuration other than screen shots, but the configuration did not get lost in the update. Thanks again, and you were a pleasure to work with.”

Kevin L. / Extol, Inc.