Connect BACnet/IP Servers to Profibus

Easily connect BACnet/IP to Profibus

460BCPBS

$941.28$957.03

SKU: 460BCPBS

INCLUDES
PRODUCT FEATURES
DATASHEETS & USERGUIDES

Connect BACnet/IP Server Devicse to a PROFIBUS Controller
The 460BCPBS moves data between up to 32 BACnet/IP Server devices and a PROFIBUS DP Controller. It’s the perfect tool to tie all the BACnet/IP devices in your automation system to PROFIBUS.

Add BACnet/IP server devices into any PROFIBUS Controller application

How Do I Use 460BCPBS-NNPB in My Application?
BACnet/IP data will be mapped into 10 PROFIBUS DP slots. The Slot can consist of up to 244 bytes of data from your BACnet/IP Server devices.

When writing from your PROFIBUS Controller to your BACnet/IP Servers, there will be up to 10 Slots each defined by the same type. Data in those slots can be mapped to your BACnet/IP devices.

Why Use Real Time Automation as a Gateway Supplier?
While there are certainly other companies offering protocol gateways, there is no one who provides the level of support and service that you receive from RTA.

When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24-hour wait.

Try the RTA difference today.

BACnet/IP Client Features

BACnet/IP Operation Modes: BACnet/IP Client
Supported Object Types: Device, BI/BO/BV, AI/AO/AV, MI/MO/MV, Character String Value
Supported Service Codes: Read Property-A, Read Property Multiple-A, Write Property-A, Write Property Multiple-A, Device Dynamic Binding-A
Maximum Connections: 32
Number Read/Write Scan Lines per Device: 200 Total - 100 reads and 100 writes
Scan Line Support: Up to 128 Objects

Profibus Slave Features

Object Model: 10 Slots in each direction
Slot Size: 2, 4, 8, 16, 24, 32 Bytes
Data Representation: int8, int16, int32, int64, uint8, uint16, uint32, uint64, Float, Double, binary8, binary 16, binary 32, Short String
Total Data Supported: 244 Bytes in each direction
Maximum Profibus DP Connections: 1

What our Customers are Saying

“I challenged a customer to get it working by the time I got back from his break room with a Coke and he indeed had it working when I got back. He then said, "It’s worth twice the price!"”

Eric P. / Kendall Electric

“Everything seems to be working as we imagined. Thanks for the great response time. I did not see any way to save the configuration other than screen shots, but the configuration did not get lost in the update. Thanks again, and you were a pleasure to work with.”

Kevin L. / Extol, Inc.