Modbus RTU Servers to BACnet MS/TP Manager Protocol Gateway
The easiest way to integrate Modbus RTU Server devices with a BACnet MS/TP building automation system. The 460MMBMS gateway allows you to move automation data between up to 32 Modbus RTU server (slave) devices and a BACnet MS/TP-controlled building automation system (BAS) or supervisory controller.
460MMBMS
Price range: $896.72 through $979.31
Connect Your Serial Modbus Devices to Your Building Management System

The 460MMBMS moves automation data between Modbus RTU server (slave) devices and a BACnet MS/TP building automation system (BAS) or supervisory controller. It serves as an ideal solution for integrating Modbus field devices (e.g., power meters, VFDs, I/O blocks, etc.) into your BACnet MS/TP building automation network without writing custom logic or downloading software.
How Does the 460MMBMS Protocol Gateway Move Data in My Application?
For most applications, the data mapping is very straight forward:
- Modbus register data is mapped to BACnet Analog Inputs (AI) and Analog outputs (AO)
- Modbus coil data is mapped to BACnet Binary Inputs (BI) and Binary Outputs (BO)
The only additional piece of information required for BACnet is adding metadata, which is nothing more than an ASCII description of each object. No other deep understanding of either protocol is required to configure the gateway. It really is that simple.
Need to modify your data as it passes from one protocol to the other? No problem. Each data mapping you apply can be modified with up to three mathematical functions. This allows you to manipulate values within the gateway itself before data reaches its destination.
Not exactly what you were looking for? Real Time Automation offers a full line of Modbus RTU protocol gateways and BACnet MS/TP protocol gateways.
Simplify Device Connectivity with Modbus Data Mapping Templates
Real Time Automation’s Modbus data mapping and template services save you time deploying multiple gateways with identical setups, pulling data from identical devices and manually mapping high-density data maps. All you need to do is provide RTA with the list of Modbus registers and coils from your device and your target protocol, and you get a custom configuration file that can be pre-loaded onto future gateways or uploaded into the gateways already deployed in your network.
- No manual entry of Modbus registers or data mapping to BACnet objects
- Customizable tag names to fit your existing naming conventions
Why Trust Real Time Automation As Your Protocol Partner?
While there are certainly other companies offering protocol gateways, no one provides the level of support and service that you receive from Real Time Automation.
- Total protocol lifecycle support
- Talk to a live person from our Wisconsin-based headquarters every time you call
- Receive honest answers and recommendations from our sales team
- Get live Enginerd support that provides timely issue resolution without opening tickets or 24-hour wait times
460MMBMS Frequently Asked Questions
The 460MMBMS is available in a variety of platform options to meet your unique application needs. Use the platform comparison table to determine the right platform for you.
Purchases can be made through authorized RTA distributors or directly from Real Time Automation. Orders may be submitted by emailing a purchase order to orders@rtautomation.com or by purchasing directly on the RTA website with a credit card.
The 460MMBMS is delivered with a 5-year warranty.
RTA offers multiple support options. Live Enginerd support is available from 8am to 5pm CST. Call 800-249-1612, email support@rtautomation.com or visit the support page.
Modbus RTU Client Features
Modbus Operation Modes: Modbus RTU ClientFunction Codes Supported: 1, 2, 3, 4, 5, 6, 15 & 16
Swapping: Byte and Word Swapping
Maximum Modbus RTU Client Devices: 32
Number Read/Write Scan Lines per RTU Server Device: 200 Total - 100 reads & 100 writes
Scan Line Support: Up to 125 Registers or 512 Coils
BACnet MS/TP Slave Features
BACnet/ MS/TP Operation Modes: BACnet MS/TP Master ResponderSupported Object Types: Device, Binary I/O, Analog I/O, Character String Value
Supported Service Codes: Read & Read Multiple-B, Write & Write Multiple-B, COV & COV unsolicited-B, Device Dynamic Binding, Dynamic Object Binding-B, Device Communication Control-B
Maximum Connections: 1
Analog Objects: Supported 1200 Input and 1200 Output
Binary Objects: Supported 1600 Input and 1600 Output