Connect BACnet MS/TP Subordinates to a Modbus RTU Manager
The 460MRSBM moves data between a Modbus RTU Manager device and up to 32 BACnet MS/TP Subordinate devices. With the 460MRSBM you’re mapping BACnet MS/TP as binary and analog values directly to your Modbus RTU Manager.
How Do I Use the 460MRSBM in My Application?
For most applications the mapping is very straight forward. Modbus register data is mapped to BACnet analog objects and Modbus coil data is mapped to binary objects in BACnet. The only additional piece required for BACnet is adding meta data which is nothing more than an ASCII description of each object. No other deep understanding of either protocol is required to configure the gateway.
It really is that simple.
Why Use Real Time Automation as a Gateway Supplier?
The 460MRSBM provides an option to access BACnet MS/TP data on a Modbus RTU network. While there are certainly a number of other companies offering stand alone gateways, there is no one who provides the level of support and service that you receive from RTA.
When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations, even if that means recommending someone else’s solution. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24 hour wait. We are unashamed of the fact that we are a smaller company because that means you mean a lot more to us. Try the RTA difference today!
Modbus RTU Server Features
Modbus Operation Modes: Modbus RTU ServerFunction Codes Supported: 1, 2, 3, 4, 5, 6, 7, 15 & 16
Swapping: Byte and Word Swapping
Maximum Modbus RTU Server Connections: 1
Contiguous Data Areas: 200 Total - 100 reads & 100 writes
Data Area Limits: 500 Contiguous Coils or 500 Contiguous Registers
BACnet MS/TP Manager Features
BACnet/ MS/TP Operation Modes: BACnet MS/TP Manager InitiatorSupported Object Types: Device, Binary, Analog, Multi-State, Character String Value
Supported Service Codes: Read Property-A, Read Property Multiple-A, Write Property-A, Write Property
Multiple-A, Device Dynamic Binding-A
Maximum Connections: 32
Number Read/Write Scan Lines per Device: 200 Total - 100 reads & 100 writes
Scan Line Support: Up to 128 Total Objects