Connect a Modbus RTU Master to a DeviceNet PLC

Easily connect a Modbus RTU and DeviceNet controller

460MRSDS

$963.56$979.31

SKU: 460MRSDS

INCLUDES
PRODUCT FEATURES
DATASHEETS & USERGUIDES

Connect Your Modbus RTU Controller with a DeviceNet PLC
The 460MRSDS connects a Modbus controller to a DeviceNet PLC. All configuration is browser based meaning there is no programming software required.

Best of all the product is Made in the USA, is always in stock and comes with a 5 year warranty.

How Do I Use the 460MRSDS in My Application?
For Most applications the mapping is very straight forward. Up to 400 bytes of data can be mapped in each direction between protocols. Register and coil data on Modbus is mapped to DeviceNet IO data blocks.

It really is that simple. Need to modify your data as it passes from one protocol to the other? No problem. Each data mapping you apply can be modified with up to 3 mathematic functions. Add 4 to a value, multiply by 4 and divide by 10 with ease.

Why Use Real Time Automation as a Gateway Supplier?
The 460MRSDS provides an option to access Modbus RTU Master data on your DeviceNet PLC. While there are certainly a number of other companies offering stand alone gateways, there is no one who provides the level of support and service that you receive from RTA.

When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations, even if that means recommending someone else’s solution. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24 hour wait. We are unashamed of the fact that we are a smaller company because that means you mean a lot more to us. Try the RTA difference today!

Modbus RTU Slave Features

Modbus Operation Modes: Modbus RTU Slave
Function Codes Supported: 1, 2, 3, 4, 5, 6, 7, 15 & 16
Swapping: Byte and Word Swapping
Maximum Modbus RTU Master Connections: 1
Contiguous Data Areas: 200 Total - 100 reads & 100 writes
Data Area Limits: 500 Contiguous Coils or 500 Contiguous Registers

DeviceNet Slave Features

DeviceNet Operation Modes: DeviceNet Slave
Supported Data Types: Int8, int16, int32, int64, uint8, uint16, uint32, uint61, float, double float, binary8, binary16, binary32
Maximum Connections: 1
Maximum Input Size: 240 Bytes in up to 15 Data Groups
Maximum Output Size: 240 Bytes in up to 15 Data Groups

What our Customers are Saying

“I challenged a customer to get it working by the time I got back from his break room with a Coke and he indeed had it working when I got back. He then said, "It’s worth twice the price!"”

Eric P. / Kendall Electric

“Everything seems to be working as we imagined. Thanks for the great response time. I did not see any way to save the configuration other than screen shots, but the configuration did not get lost in the update. Thanks again, and you were a pleasure to work with.”

Kevin L. / Extol, Inc.