Modbus TCP Client to BACnet/IP Servers Protocol Gateway
The easiest way to connect Modbus TCP Clients to BACnet/IP field devices. The 460MSBC gateway allows you to move automation data between up to 10 Modbus TCP clients and up to 32 BACnet/IP Server devices.
460MSBC
Price range: $896.72 through $1,035.00
Connect Your Modbus TCP Network to Your Modern BACnet/IP Field Devices

The 460MSBC moves automation data between up to 10 Modbus TCP clients and up to 32 BACnet/IP server devices. It’s a perfect tool to bridge the gap between your industrial automation control network and the devices running your facility without writing custom logic or downloading software.
How Does the 460MSBC Protocol Gateway Move Data in My Application?
For most applications, the data mapping is very straight forward:
- Modbus register data is mapped to BACnet Analog Inputs (AI) and Analog outputs (AO)
- Modbus coil data is mapped to BACnet Binary Inputs (BI) and Binary Outputs (BO)
The only additional piece of information required for BACnet is adding metadata, which is nothing more than an ASCII description of each object. No other deep understanding of either protocol is required to configure the gateway. It really is that simple.
Need to modify your data as it passes from one protocol to the other? No problem. Each data mapping you apply can be modified with up to three mathematical functions. This allows you to manipulate values within the gateway itself before data reaches its destination.
Not exactly what you were looking for? Real Time Automation offers a full line of Modbus TCP protocol gateways and BACnet/IP protocol gateways.
Simplify Device Connectivity with Modbus Data Mapping Templates
Real Time Automation’s Modbus data mapping and template services save you time deploying multiple gateways with identical setups, pulling data from identical devices and manually mapping high-density data maps. All you need to do is provide RTA with the list of Modbus registers and coils from your device and your target protocol, and you get a custom configuration file that can be pre-loaded onto future gateways or uploaded into the gateways already deployed in your network.
- No manual entry of Modbus registers or data mapping to BACnet objects
- Customizable tag names to fit your existing naming conventions
Why Trust Real Time Automation As Your Protocol Partner?
While there are certainly other companies offering protocol gateways, no one provides the level of support and service that you receive from Real Time Automation.
- Total protocol lifecycle support
- Talk to a live person from our Wisconsin-based headquarters every time you call
- Receive honest answers and recommendations from our sales team
- Get live Enginerd support that provides timely issue resolution without opening tickets or 24-hour wait times
460MSBC Frequently Asked Questions
The 460MSBC is available in a variety of platform options to meet your unique application needs. Use the platform comparison table to determine the right platform for you.
Purchases can be made through authorized RTA distributors or directly from Real Time Automation. Orders may be submitted by emailing a purchase order to orders@rtautomation.com or by purchasing directly on the RTA website with a credit card.
The 460MSBC is delivered with a 5-year warranty.
RTA offers multiple support options. Live Enginerd support is available from 8am to 5pm CST. Call 800-249-1612, email support@rtautomation.com or visit the support page.
Modbus TCP/IP Server Features
Modbus Operation Modes: Modbus TCP/IP ServerFunction Codes Supported: 1, 2, 3, 4, 5, 6, 7, 15 & 16
Swapping: Byte and Word Swapping
Maximum Modbus TCP/IP Client Connections: 10
Contiguous Data Areas: 200 Total - 100 reads & 100 writes
Data Area Limits: 500 Contiguous Coils or 500 Contiguous Registers
BACnet/IP Client Features
BACnet/IP Operation Modes: BACnet/IP ClientSupported Object Types: Device, BI/BO/BV, AI/AO/AV, MI/MO/MV, Character String Value
Supported Service Codes: Read Property-A, Read Property Multiple-A, Write Property-A, Write Property Multiple-A, Device Dynamic Binding-A
Maximum Connections: 32
Number Read/Write Scan Lines per Device: 200 Total - 100 reads and 100 writes
Scan Line Support: Up to 128 Objects